WET AREA SHOCK PROTECTION (KITCHEN/BATH) • AUDITED OPERATIONAL SPEC

20-Amp Self-Testing GFCI Receptacle

⚡ FIELD SPECIFICATION SUMMARY

Detects ground faults as low as 4 to 6 milliamperes and disconnects power within 25 milliseconds to prevent fatal electrocution.

Audited Engineering & Performance Metrics

WIRE GAUGE12 AWG Copper Wire (20A Breaker)
TERMINAL TORQUE14 - 16 inch-pounds
BOX VOLUME3.5 cu in internal displacement
NEC CODENEC 210.8 (Within 6ft of sinks)
STRIP LENGTH1/2 Inch Straight Insertion
GROUND STYLELine vs Load Terminals Isolated
📋Specialist Advisory: Greg Callahan (Master Electrician & Code Inspector)

Critical: The tape covering 'LOAD' terminals must remain intact unless powering downstream slave outlets. Hook incoming source only to 'LINE'.

GFCI & 3-Way Switch Diagnostic Wiring Card (.PDF)