VOLTGAUGE • AUDITED FIELD MATRIX

Receptacle, Switch & Box Sizing Matrix

National Electrical Code (NEC) ampacity, torque specs, terminal clearances, and cubic-inch box fill calculations.

🔌Standard Living Area Branch Outlet

15-Amp Tamper-Resistant Duplex Receptacle

wire gauge:14 AWG Copper Wire (15A Breaker)
terminal torque:12 - 14 inch-pounds (Screw Terminal)
box volume:2.0 cu in per device fill (NEC 314.16)
View Operational Protocol ›
⚡Wet Area Shock Protection (Kitchen/Bath)

20-Amp Self-Testing GFCI Receptacle

wire gauge:12 AWG Copper Wire (20A Breaker)
terminal torque:14 - 16 inch-pounds
box volume:3.5 cu in internal displacement
View Operational Protocol ›
💡Dual-Location Lighting Control

15-Amp 3-Way Toggle Wall Switch

wire gauge:14/3 NM-B Romex (Black, Red, White, Bare)
terminal torque:12 inch-pounds
box volume:2.0 cu in device fill
View Operational Protocol ›
🛡️Main Panel Arc & Ground Fault Protection

Dual-Function AFCI/GFCI Circuit Breaker (20A)

wire gauge:12 AWG Hot & Neutral Direct to Breaker
terminal torque:25 - 35 inch-pounds (Panel Lug)
box volume:N/A (Load Center Panel Space)
View Operational Protocol ›
🌧️Exterior & Patio Code Compliance

Weather-Resistant (WR) Outdoor GFCI Outlet

wire gauge:12 AWG UF-B Underground Feeder
terminal torque:14 - 16 inch-pounds
box volume:3.5 cu in deep box requirement
View Operational Protocol ›
🎛️Energy-Efficient Lighting Modulation

Universal LED Slide Dimmer with Preset

wire gauge:14 AWG stranded pigtails included
terminal torque:Wire Nut / Wago 221 Lever Nut
box volume:2.5 cu in large heatsink
View Operational Protocol ›